Preferred worldwide for fiscal measurement, the next-generation Daniel™ SeniorSonic™ 3414 Four-Path Ultrasonic Flow Meter retains the field-proven, British Gas-chordal design while significantly increasing sampling speed with ultra-fast Daniel 3410 Series Electronics. This powerful, high-performance meter minimizes measurement uncertainty by enabling rapid detection of changing flow dynamics such as blockages upstream of the meter, abnormal flow profiles and liquid hydrocarbons. MeterLink™ Software displays a wealth of predictive diagnostics generated by the meter, providing expert flow analysis, flow disturbance alerts and suggested corrective actions, to expedite detection before measurement is impacted.
Specifications
Line Sizes
DN100 to DN1050 (4-in to 42-in)
DN100 to DN150 (4-in to 6-in) are 45° dual X orientation
DN200 (8-in) and larger are British Gas (BG) orientation
Fluid Type
Gas
Accuracy
±0.1% of reading relative over entire flow calibration range
Repeatability
±0.05% of reading for 5 to 100 ft/s (1.5 to 30.5 m/s)
Velocity
Rated up to 100 ft/s (30 m/s) with over-range performance exceeding 125 ft/s (38 m/s) on some sizes
Operating Temperature Range
T-21 Transducers: -20°C to +100°C (-4°F to +212°F)T-22 Transducers: -50°C to +100°C (-58°F to +212°F)
Operating Pressure Range
T-21/T-22 Transducers: 689 to 27,579 kPag (100 to 4,000 psig)T-21/T-22 Transducers: 345 kPag (50 psig) minimum operating pressure available with reduced QmaxT-22 Transducers: 0 to 689 kPag (0 to 100 psig) isolated transducer mou
Materials
Carbon steel and stainless steel
Features
Speed issue resolution with 3D view of the flow profile that indicates swirl, crossflow, asymmetry and turbulence
Reduce manual errors with automatic calculations of AGA 8 Compressibility and AGA 10 Speed of Sound
Expedite flow disturbance detection with patented transducer synchronization that prevents interference and noise
Reduce measurement uncertainty with process alerts for wall buildup, liquids, blockage and deviating gas quality
Increase I/O with new Type 4 CPU Module with up to six frequency or digital outputs
T-200 Transducers are safely extractable under pressure without special tools (for line sizes up to 12”)
Increase I/O with new Type 4 CPU Module with up to six frequency or digital outputs
T-200 Transducers are safely extractable under pressure without special tools (for line sizes up to 12”)
Thiết Bị Đo Lưu Lượng Siêu Âm Daniel SeniorSonic 3414 - Emerson Việt Nam
- AT2E
- Baumuller
- Bircher
- BCS Italy
- Bernard Control
- Beckhoff
- Beijer
- CS Instruments
- CEIA
- DECA WELD
- Elau Schneider
- Fireye
- Finetek
- Gastron
- IBA
- Insert Deal
- Knick
- Koganei
- Keofitt
- Keller - Its
- Kiepe Elektrik
- Kometer Flowmeter
- Lapar Valve
- Mark - 10
- Matsushima
- Minimax
- Nireco
- Ohkura
- Pavone Sistemi
- Pora
- Red lion
- Riels
- SOR
- Staubli
- TDK Lambda
- Teclock
- Vega
- YTC (Young Tech)
- Wago
- FOX THERMAL
- ORBINOX
- Clyde Pneumatic Conveying
- KREBS - RIEDEL
- PCI Instrument
- CEMB
- BARKSDALE
- INTORQ
- SITEC
- Spohn Burkhardt
- Emerson
- KSR KUEBLER
- Dosatec SA
- Thwing-Albert
- OKAZAKI
- TEK TROL
- NAGANO KEIKI
- Danh mục khác
-
Trực tuyến:10
-
Hôm nay:839
-
Tuần này:3637
-
Tháng trước:9380
-
Tất cả:1906793