EMA series.
- Certified according to ECAC performance requirements for Type B and Type A (Optional) Liquid Explosive Detection Systems (LEDS)
- Accurate automatic inspection of sealed and unsealed LAGs (Liquids, Aerosols and Gels) in ~ 5 sec. (Type B) and ~ 4 sec. (Type A)
- Compact size and ergonomic design
- Certified to screen liquids in clear, colored and opaque plastic and glass, metal and metallized containers
- Very low combined Nuisance Alarm Rate: < 0.4%
- No-ionizing source or part in movements
- No maintenance required
The EMA is a compact device designed for the analysis of liquid containers and their contents with the goal of detecting the possible presence of explosive precursors and explosive liquids. When the operator places the bottle in the inspection cavity, its presence is automatically detected and the analysis is performed in ~ 5 seconds.
Specifications
Key features
- Integrated Type B and Type A Standard 3 certified System
- Automatic inspection of any type of containers
- Inspection time in ~ 5 seconds (type B) and ~ 4 seconds (type A)
- Multiple simultaneous sensing technologies
- Minimum installation space
- Minimum operator training required
- All solid state
- No mechanical parts in movements
- No-ionizing or laser sources
- No maintenance required
Multiple sensing technology
- Wideband Radio Frequency (R.F.)
- Infrared (IR)
- Magnetic Inductive
- Gravimetric
Inspection Characteristics
- Commercial Bottles of any shape and materials including plastic, glass, metal with capacity ranging from 100 ml to 2000 ml
- Type A sample cups volume: 10 ml
- Initial Start-up time: 15 sec. max
- Analysis type: automatic
- Analysis time: 5 sec. typical (type B) and 4 sec. typical (type A)
Detectable substances
- Explosive precursors and explosive liquids
Alarm Signalling
Light color | Display message | Meaning |
Green | OK | Allowed liquid |
Yellow | Not allowed product | Alarm of medium intensity |
Red | Not allowed product | Alarm of high intensity |
Acoustic alarmThreat classification availableOperator interface
- Easy to read high-contrast graphic display
- High durability stainless steel function keys
- Programmability of all the parameters protected by passwords
Function and calibration control
- Automatic calibration, continuously running
- Manual verification of calibration, performed by the operator through Pass/No-Pass reference test pieces (according to the operational procedures)
Communication capability
- RS-232 serial interface
- Ethernet network interface
Remote control and Ethernet Networking Functions
- Available through the CEIA NetID Management software
- Programming
- Statistical Data Collection
- Maintenance
- Firmware upgrade
Degree of protection
- IP 20 (IEC 60529)
Weight
- 17 kg (type B only)
- 17.5 kg (type B and type A)
Main Electronics Features
- High integration SMT
- 32-bit flash-based microcontrollers
- 32-bit DSP
- Low power and high reliability
- Very low power inspection field, confined in the analysis compartment, completely safe for both the operator and the liquid
- No ionizing radiation or radioactive sources
- No laser sources
Main Mechanical Features
- Constructed entirely in AISI304 Stainless Steel
- Anti-fingerprint surface treatment
- Rugged and Durable
- Compact and Aesthetically pleasing
Installation and Maintenance
- Automatic adjustment to environmental conditions
- No initial or periodic calibrations required
- Firmware upgradeable via RS232 or Ethernet interface
- No periodical maintenance or consumables required
- Built-in automatic calibration and self-diagnosis system
Certification and conformity
- Standard 3 Certified according to ECAC performance requirements for Type B Liquid Explosive Detection Systems
- Standard 3 Certified according to ECAC performance requirements for Type A Liquid Explosive Detection Systems
- Conforms to the currently applicable International Standards for Electrical Safety and EMC
Power Supply
- 115/230V~ ±15%, 50/60 Hz ±10%, 15W
Environmental conditions
- Operating temperature: 0°C to +40°C
- Storage temperature: -10°C to +60°C
- Operating Relative humidity: 0 to 95% (without condensation)
- Storage Relative humidity: 0-98%, without condensation
NATO Stock Number
- 6665-151805235
- 6665-151805236
Type A analyser (optional)
Thiết bị kiểm tra chất lỏng trong chai EMA CEIA - CEIA VietNam
- AT2E
- Baumuller
- Bircher
- BCS Italy
- Bernard Control
- Beckhoff
- Beijer
- CS Instruments
- CEIA
- DECA WELD
- Elau Schneider
- Fireye
- Finetek
- Gastron
- IBA
- Insert Deal
- Knick
- Koganei
- Keofitt
- Keller - Its
- Kiepe Elektrik
- Kometer Flowmeter
- Lapar Valve
- Mark - 10
- Matsushima
- Minimax
- Nireco
- Ohkura
- Pavone Sistemi
- Pora
- Red lion
- Riels
- SOR
- Staubli
- TDK Lambda
- Teclock
- Vega
- YTC (Young Tech)
- Wago
- FOX THERMAL
- ORBINOX
- Clyde Pneumatic Conveying
- KREBS - RIEDEL
- PCI Instrument
- CEMB
- BARKSDALE
- INTORQ
- SITEC
- Spohn Burkhardt
- Emerson
- KSR KUEBLER
- Dosatec SA
- Thwing-Albert
- OKAZAKI
- TEK TROL
- NAGANO KEIKI
- Danh mục khác
-
Trực tuyến:3
-
Hôm nay:434
-
Tuần này:3521
-
Tháng trước:12219
-
Tất cả:1636030